Max width 5700mm
Max height 6000mm
Panel thickness 52mm
Door U-value 0.4 W/m2/°C.
Sideroom required 200mm
Headroom required 150mm
Weight 20kg/m2
Performance
Performance in accordance with BS EN 13241-1:2003 (based on door tested Aug’05) .
• Forces for Manual Operation – Pass
• Operating Forces – Pass
• Watertightness – Class 2 (50pa)
• Air Permeability – Class 2
• Durability of Performance – Pass (110,000 continuous cycles in 60 days)
• Life expectancy – more than 20 years
• Wind pressure(2) - 0.7kN/m2 (6m high door), 1.1kN/m2 (5m high door), 1.7kN/m2 (4m high door), 3.1kN/m2 (3m high door).
Acoustic performance of the panel – Average weighted SRI, RW Index tested at 29dB. Overall door 25dB (based on test result as University of Salford March ’03)
Threshold
Standard A 140 x 10mm thick extruded aluminium plate with 30° chamfered edges and anti-slip grooves fixes directly to the floor to form a water bar, presents a level surface for the door to seal against, minimises bottom seal wear as the door folds, and provides a solid location point for floor bolts.
Option - No threshold supplied.
It is recommended that a threshold plate is installed. By not installing a threshold plate, the effectiveness of the bottom seals may be reduced, and wear of bottom seals may be expedited.
Top Track
The top guide track is a galvanised steel channel mounted back to the surround frame with 6mm pressed steel brackets. Top guide rollers are nylon guide wheels running on steel shafts mounted within black aluminium extrusions.
Wicket Door Option
Standard - None fitted.
Option 1 - Lever furniture. Wicket door opens outwards. Hardware comprises a Briton 5520 mortise sashlock, 25mm low-profile anodised aluminium lever handles, external Europrofile cylinder with internal thumbturn, 1½ pairs of stainless steel butt hinges and a hidden door limiting stay. 85mm high step with 40mm wide aluminium threshold strip.
Option 2 - Emergency escape furniture. Wicket door opens outwards. Hardware comprises a Briton 379 panic bar, external override cylinder and finger latch, 1½ pairs stainless steel butthinges and a hidden overhead door limiting stay. 85mm high step with 40mm wide aluminium threshold strip.
Windows - Vison Panels
Standard - None fitted.
Option 1 - Black thermoplastic ‘snap-lock’ window with integral double-glazed units (2.5~15~2.5) SAN RS UV (scratch and UV resistant) outside, PMMA UV inside. Overall frame size 770mm x 430mm.
Option 2 - Thermally broken aluminium window frame with one-piece inner liner tray. Window units are double glazed (4~20~4), argon filled, low E toughened glass. Frames are polyester powder coated in matt black to RAL 9005(M), fully sealed.
Choice of frame sizes as follows: 400mm x 600mm, 600mm x 600mm, 400mm x 1200mm, 600mm x 1200mm.
Locking Systems
Standard - A drop bolt and a black thermoplastic easygrip pull handle are fitted internally between each pair of leaves.
(to leading leaf of 2+0, 2+2 leaf doors only).
A bottom guide pin engages in a cast aluminium floor shoe fitted to the threshold, holding the leading edge(s) firm. A black thermoplastic easy-grip pull handle is fitted internally.
Option 1 - A top and bottom espagnolette shoot bolt operated via an internal, non-lockable lever handle is fitted in lieu of a drop bolt and pull handle.