The Hormann APU67 Thermo Industrial Sectional Doors offers excellent thermal insulation thanks to its glazing beads and steel sections with thermal break.
Without Wicket Door
Door Size: Max. width 10000mm
Door Size: Max. height 7500mm
Thermal insulation EN 13241-1, Appendix B EN 12428
U-value in W/(m².K) for a door surface 5000 x 5000mm
Standard triple pane = 2.3
With ThermoFrame = 2.2
Optional climatic double pane, single-pane safety glass = 1.6
With ThermoFrame = 1.5
With Wicket Door
Door Size: Max. width 7000mm
Door Size: Max. height 7500mm
Thermal insulation EN 13241-1, Appendix B EN 12428
U-value in W/(m².K) for a door surface 5000 x 5000mm
Standard triple pane = 2.3
With ThermoFrame = 2.2
For more information view the Hormann Industrial Sectional Doors Brochure.
- Specification
Performance Characteristics According to EN 13241-1 | ||||
---|---|---|---|---|
Construction and quality features | APU F42 | APU F42 Thermo |
APU 67 | |
Resistance to wind load EN 12424 | Door without wicket door, class | 3 6) | 3 6) | – |
Door with wicket door, LZ ≤ 4000, class | 3 6) | 3 6) | 3 6) | |
Door with wicket door, LZ > 4000, class | 2 7) | 2 7) | 2 7) | |
Door with wicket door, LZ ≤ 8000, class | – | – | 3 6) | |
Door with wicket door, LZ > 8000, class | – | – | 2 7) | |
Water tightness EN 12425 | Door without wicket door, class | 3 (70 Pa) | 3 (70 Pa) | 3 (70 Pa) |
Air permeability EN 12426 | Door without wicket door, class | 2 8) | 2 8) | 2 8) |
Door with wicket door, class | 1 9) | 1 9) | 1 9) | |
Acoustic insulation EN 717-1 | Door without wicket door Rw = . . . dB | 23 | 23 | 23 |
Door with wicket door Rw = . . . dB | 22 | 22 | 22 | |
Thermal insulation value EN 13241-1, appendix B EN 12428 |
Door without wicket door, U = W/(m2·K) 2) | 3.4 (3.3 4)) | 2.9 (2.8 4)) | 2.1 (2.0 4)) |
– Optional triple glazing, U = W/(m2·K) 2) | 3.0 (2.9 4)) | 2.5 (2.4 4)) | – | |
– Optional quadruple glazing, U = W/(m2·K) 2) | – | – | 1.8 (1.7 4)) | |
– Optional climatic double panes (made of single-pane safety glass) U = W/(m2·K) 2) | 2.5 (2.4 4)) | 2.0 (1.9 4)) | 1.6 (1.5 4)) | |
– Optional double panes (made of single-pane safety glass) U = W/(m2·K) 2) | 3.4 (3.3 4)) | 2.9 (2.8 4)) | 2.6 (2.5 4)) | |
Door with wicket door, U = W/(m2·K) 2) | 3.6 (3.6 4)) | 3.1 (3.1 4)) | 2.3 (2.2 4)) | |
– Optional triple glazing, U = W/(m2·K) 2) | 3.2 (3.1 4)) | 2.7 (2.6 4)) | – | |
– Optional quadruple glazing, U = W/(m2·K) 2) | – | – | 2.0 (1.9 4)) | |
– Section, U = W/(m2·K) | – | – | – | |
Design | Self-supporting | ● | ● | ● |
Depth, mm | 42 | 42 | 67 | |
Door sizes | Max. width mm, LZ | 8000 | 7000 | 10000 |
Max. height mm, RM 3) | 7500 | 7500 | 7500 | |
Material, door leaf | Steel, double-skinned, 42 mm | ● | ● | – |
Steel, double-skinned, 67 mm | – | – | ● | |
Aluminium, standard profile | ● | – | – | |
Aluminium, profile with thermal break | – | – | ● | |
Surface, door leaf | Galvanized steel, coated RAL 9002 | ○ | ○ | ○ |
Galvanized steel, coated RAL 9006 | ● | ● | ● | |
Galvanized steel, coated RAL to choose | ○ | ○ | ○ | |
Anodised aluminium E6 / C0 (previously E6 / EV 1) | ● | ● | ● | |
Aluminium coated in RAL to choose | ○ | ○ | ○ | |
Wicket door | ○ | ○ | ○ | |
Side Door | Matching the door | ○ | ○ | ○ |
Glazings | Type A section window | – | – | – |
Type D section window | – | – | – | |
Type E section windows | – | – | – | |
Aluminium glazing frame | ● | ● | ● | |
Seals | All-round on 4 sides | ● | ● | ● |
Intermediate seal between the door sections | ● | ● | ● | |
ThermoFrame | PVC hard / soft seal | ○ | ○ | ○ |
Locking systems | Internal latches | ● | ● | ● |
Outside / inside locking | ○ | ○ | ○ | |
Anti-lift kit | For doors of up to 5 m with shaft operator | ● | ● | ● |
Safety equipment | Finger trap protection | ● | ● | – |
Side trap guards | ● | ● | ● | |
Spring break safeguard for manual operation | ● | ● | ● | |
Safety catch for doors with shaft operator | ● | ● | ● |
● = Standard | * With glazing VG, E2 and G2 | |
○ = Optional | ** Top door section | |
1) With optional double pane (single-pane safety glass) | 4) Optionally with Thermoframe | 7) Class 2 = 0.45 kN/ m2 or 96 km/h |
2) For a door surface of 5000 × 5000 mm | 5) Door width up to 5500 mm | 8) Class 2 = 12 m3/m2h |
3) Door height above 7000 mm on request (not with door type ALR F42 Glazing) |
6) Class 3 = 0.7 kN/ m2 or 120 km/h | 9) Class 1 = 24 m3/m2h |